Particle filter half mask | Individually packed
Dolomite dust tested according to EN 149
2,98 € Original price was: 2,98 €.1,90 €Current price is: 1,90 €.
0,30 € Original price was: 0,30 €.0,19 €Current price is: 0,19 €. / pcs
Product contains: 10 pcs
incl. VAT
plus shipping costs
Delivery time: 2 - 3 days
CE Certified | Ja, CE 0598 |
---|---|
Tested according to | EN 149:2001 + A1:2009 |
Packaging unit (piece) | 10 |
Mask packing | Individually packed |
Layers | 5 |
Color | green, navy-blue, white |
Model | KF-H 9421 |
Brand | |
MHD |
KINGFA FFP2 NR D particle filter half mask, dolomite dust tested according to EN 149:2001 + A1:2009
Kingfa FFP2 NR D masks have a very good fit and can be worn comfortably for a long time. The nose section is padded with a foam and thus has a very comfortable fit. The masks are individually packaged and available in navy blue, white and green.
Dolomite dust tested
The EN 149 test (dolomite dust test) is a voluntary test and subjects the mask to an absolute endurance test.
In occupational safety, this test is even a basic requirement and the mask is given the D mark after passing it.
For use in the medical field for infection protection, this test means increased safety, since the KINGFA FFP2 masks have an increased filtering capacity and a very high absorption capacity.
Technical details:
Particle filtration efficiency (PFE) ≥ 94%.
Breathing resistance (inhalation, 30 L/min): ≤ 0.7mbar
Breathing resistance (inhalation, 95 L/min) : ≤ 2.4mbar
Breathing resistance (exhalation, 1600 L/min): ≤ 3.0mbar
Total Inward Leakage (TIL) : For particle filtering half masks as specified by the manufacturer, at least 46 of the 50 individual exercise results for total inward leakage shall not be greater than 11% for FFP2, and in addition, at least 8 of the 10 individual wearer arithmetic averages for total inward leakage shall not be greater than 8% for FFP2.
Flammability: ≤ 5S
Dead space: ≤ 1.0%
Mit dem best medical Newsletter erhalten Sie ständig aktuelle Informationen zu Preisänderungen und Rabattaktionen! Melden Sie sich jetzt an!
With the best medical newsletter you will constantly receive up-to-date information on current prices / offers and also on new vouchers.
Basic parameters and performance indicators | |
---|---|
Sample size | 2 x 8 (16) test wells | 0.2 ml tubes (30-100 µl), 8-strip tube with 8-strip cap is recommended |
Response system | 10 – 10¹º Kopien |
Fluorescent dye | F1: FAM, SYBR Greenl etc. F2: HEX, VIC, JOE, etc. F3: ROX, TEXAS RED, etc. F4: Cy5 etc. |
Fluorescence detection time of the entire plate | Within 2 seconds |
Temperature range | 10 – 100 °C |
Temperature uniformity | ±0,1 °C (@58 °C) |
Temperature accuracy | ±0,1 °C (@58 °C) |
Heating rate (average) | >8,0 °C/s |
Heating rate (average) | >10,5 °C/s |
Cooling rate (average) | >5,0 °C/s |
Cooling rate (maximum) | >7,5 °C/s |
Temperature range of the hot lid | 30 – 120 °C |
Repeatability of the fluorescence intensity test | CV <0,5 % |
Repeatability of the sample test | CV <1 % |
Linearity of the sample | Linear regression coefficient R ≥ 0.98 |
Fluorescence linearity | Linear regression coefficient R ≥ 0.98 |
Device communication interface | Network connection / serial port |
Input power | 100 – 240 VAC 50/60 HZ Max. 800 VA |
Dimensions | 380 x 300 x 185 mm (size of the outer box: 520 x 410 x 360 mm) |
Net weight | 9,8 kg |