Anterior nasal swab, deep nasal swab, pharyngeal swab and saliva test “Lolli test”.
Best sensitivity of all tests according to PEI!
4,76 € 4,00 € exkl. MwSt.
0,19 € / pcs
Product contains: 25 pcs
incl. VAT
plus shipping costs
Out of stock
Product contains: 25 pcs
Artikelnummer: Y690 Categories Anterior nasal swab, deep nasopharyngeal swab and lollipop test, Saliva test, Anterior & deep nasal swab, Deep Nasal & Throat Swab, Rapid & Self Tests, Staffelpreis Profitest EN, Anterior nasal swab, Tongue dressing test, Anterior nasal swab and deep nasopharyngeal swab, Professional approval Tag BfArM listedLay approval | No – For healthcare professionals only |
---|---|
BfArM listed | Yes |
BfArM Listennummer | AT1188/21 |
Paul Ehrlich Institute listed? | Yes |
CE Certified | Ja |
Sensitivity in % | 96,77 |
Packaging unit (piece) | 25 |
Scope of delivery | 25 x SARS-CoV-2 Antigen Test Cassettes |
Ideale Versandeinheit | |
Brand | |
MHD |
Green Spring SARS-CoV-2 Antigen Rapid Test 4 in 1
The Green Spring Antigen Test offers all four testing options in one: saliva test “lollipop test”, anterior & posterior nasal swab and throat swab. This makes the Green Spring Test a flexible universal test.
According to the Paul Ehrlich Institute, the Green Spring TS25. G01 offers the best sensitivity of all antigen rapid tests approved in Germany (currently 122 tests, as of 12/2021).
In the box of 25 you get the utensils for a comfortable lollipop or anterior nasal swab test as well as the possibility to do a deep nasal & throat swab. Also included is a holding device for the 25 buffer vials. Due to its ease of use, the Green Spring Antibody Rapid Test is especially recommended for kindergartens, testing stations, testing centers, etc.
According to the manufacturer, the Green Spring SARS-CoV-2 Antigen Rapid Test Set (colloidal gold) can detect the Omikron variant (B.1.1.529).
Mit dem best medical Newsletter erhalten Sie ständig aktuelle Informationen zu Preisänderungen und Rabattaktionen! Melden Sie sich jetzt an!
With the best medical newsletter you will constantly receive up-to-date information on current prices / offers and also on new vouchers.
Basic parameters and performance indicators | |
---|---|
Sample size | 2 x 8 (16) test wells | 0.2 ml tubes (30-100 µl), 8-strip tube with 8-strip cap is recommended |
Response system | 10 – 10¹º Kopien |
Fluorescent dye | F1: FAM, SYBR Greenl etc. F2: HEX, VIC, JOE, etc. F3: ROX, TEXAS RED, etc. F4: Cy5 etc. |
Fluorescence detection time of the entire plate | Within 2 seconds |
Temperature range | 10 – 100 °C |
Temperature uniformity | ±0,1 °C (@58 °C) |
Temperature accuracy | ±0,1 °C (@58 °C) |
Heating rate (average) | >8,0 °C/s |
Heating rate (average) | >10,5 °C/s |
Cooling rate (average) | >5,0 °C/s |
Cooling rate (maximum) | >7,5 °C/s |
Temperature range of the hot lid | 30 – 120 °C |
Repeatability of the fluorescence intensity test | CV <0,5 % |
Repeatability of the sample test | CV <1 % |
Linearity of the sample | Linear regression coefficient R ≥ 0.98 |
Fluorescence linearity | Linear regression coefficient R ≥ 0.98 |
Device communication interface | Network connection / serial port |
Input power | 100 – 240 VAC 50/60 HZ Max. 800 VA |
Dimensions | 380 x 300 x 185 mm (size of the outer box: 520 x 410 x 360 mm) |
Net weight | 9,8 kg |