The online store for doctors, pharmacies, care and test centers

Finecare CK-MB Rapid Test

25 test cassettes for Finecare measuring devices

Price

172,50  144,96  exkl. MwSt.

6,90  / pcs

Product contains: 25 pcs

incl. VAT

Delivery time: 2 - 3 days

Product contains: 25 pcs

Artikelnummer: Y911-W205 Category

Additional information

Result after

15 minutes

Sample material

Whole blood, blood plasma, serum

Sample volume

75 μL

Measuring range

0.3 to 100 ng/mL

Ergebnis

Quantitativ

Scope of delivery

1 x ID chip
25 x Individually packed test cassettes
25 x Pre-filled buffer vial
25 x Pipette tips
1 x Instruction manual

Lay approval

No – For healthcare professionals only

CE Certified

Ja

For in vitro diagnosis of myocardial infarction (CK-MB)

Additional downloads

This might also interest you:

Y911-W202
Auf Lager

Finecare NT-proBNP Rapid Test

172,50  144,96  exkl. MwSt.
25 test cassettes for Finecare measuring devices
Y911-W209
Auf Lager

Finecare PSA Rapid Test

172,50  144,96  exkl. MwSt.
25 test cassettes for Finecare measuring devices
Y911-W231
Auf Lager

Finecare T3 Rapid Test

172,50  144,96  exkl. MwSt.
25 test cassettes for Finecare measuring devices

Aktuelle Preise und Rabatte EXKLUSIV für Sie!

Mit dem best medical Newsletter erhalten Sie ständig aktuelle Informationen zu Preisänderungen und Rabattaktionen! Melden Sie sich jetzt an!

The best medical Newsletter

With the  best medical newsletter you will constantly receive up-to-date information on current prices / offers and also on new vouchers.

 

EGENS PCR test device YS qPCR-1

Technical details

Basic parameters and performance indicators
Sample size
2 x 8 (16) test wells | 0.2 ml tubes (30-100 µl), 8-strip tube with 8-strip cap is recommended
Response system
10 – 10¹º Kopien
Fluorescent dye
F1: FAM, SYBR Greenl etc. F2: HEX, VIC, JOE, etc. F3: ROX, TEXAS RED, etc. F4: Cy5 etc.
Fluorescence detection time of the entire plate
Within 2 seconds
Temperature range
10 – 100 °C
Temperature uniformity
±0,1 °C (@58 °C)
Temperature accuracy
±0,1 °C (@58 °C)
Heating rate (average)
>8,0 °C/s
Heating rate (average)
>10,5 °C/s
Cooling rate (average)
>5,0 °C/s
Cooling rate (maximum)
>7,5 °C/s
Temperature range of the hot lid
30 – 120 °C
Repeatability of the fluorescence intensity test
CV <0,5 %
Repeatability of the sample test
CV <1 %
Linearity of the sample
Linear regression coefficient R ≥ 0.98
Fluorescence linearity
Linear regression coefficient R ≥ 0.98
Device communication interface
Network connection / serial port
Input power
100 – 240 VAC 50/60 HZ Max. 800 VA
Dimensions
380 x 300 x 185 mm (size of the outer box: 520 x 410 x 360 mm)
Net weight
9,8 kg